Siemens SIMATIC S7-1500 characteristics

Siemens SIMATIC S7-1500 characteristics

SIMATIC PLC 1500

Characteristics of Siemens SIMATIC S7-1500

Siemens SIMATIC S7-1500 controllers have a modular design and consist of up to 32 modules that can be individually combined. The S7-1500 automation system supports single-level configurations in which all modules are mounted on a single DIN rail. Such a system includes:

  1. Controller - a CPU of various capacities with integrated PROFINET interface or PROFINET and PROFIBUS interface for connection of distributed I/O and communication between programmer, operator panel, other SIMATIC controllers or devices outside the Siemens family. Various processor versions are available for the SIMATIC S7-1500:
  • standard processors (MFP version) capable of executing C/C++ code on the controller,
  • compact processors with digital and analog inputs and outputs, as well as counter inputs or high-speed outputs for integrated technology functions directly in the processor,
  • Fail-Safe processors (MFP version capable of executing C/C++ code on the controller) for executing standard and security-related programs on the same computer,
  • Technology processors with enhanced Motion Control functions.
  1. Signal modules for digital and analog input/output.
  2. Technology modules, e.g., for high-speed counting, position detection or measurement functions.
  3. Communication modules and communication processors to expand controllers with communication interfaces

Additional modules to be used

  • Power supply modules (PS) for powering the internal electronics of S7-1500 modules via the backplane bus in case the processor output power to the backplane bus is not sufficient for all connected modules.
  • Load current (PM) power modules for connecting SIMATIC S7-1500 to 120/230 V AC supply voltage.
  • Interface modules for connecting distributed I/O based on the S7-1500.

Input/output modules

Types of modules for use in SIMATIC S7-1500/ET 200MP:

  • standard and safety digital input/output modules,
  • digital input/output modules,
  • analog input/output modules,
  • technology modules for counting and positioning,
  • communication modules for IO-Link and point-to-point communication and bus connection.

To provide users with optimal application scalability, different classes of modules are available and are labeled accordingly.

  • BA (Basic) - simple, economical modules without diagnostics and parameters.
  • ST (Standard) - modules with module- or load group-specific diagnostics (or if applicable with parameters for analog modules, 0.3% accuracy class).
  • HF (High Feature) - modules with channel-specific diagnostics and parameter setting, as well as support for isosynchronous mode. For analog modules, 0.1% accuracy class, increased immunity and galvanic isolation.
  • HS (High Speed) - modules with extremely short filtering and conversion times for very high-speed applications, with support for isosynchronous mode (e.g., 8-channel analog modules with a basic execution time of 62.5 µs, regardless of the number of active channels).

 

Communication interfaces

Process communication via PROFINET IO

SIMATIC S7-1500 is connected to the PROFINET IO bus system via the integrated PROFINET interface and enables distributed automation configuration with defined response times and highly precise plant behavior. Distributed I/O via PROFINET IO is treated from the user's perspective as centralized I/O (same configuration, addressing and programming).

Process communication via PROFIBUS DP

SIMATIC S7-1500 (not S7-1500R/H) is connected to the PROFIBUS DP bus system via a communication module or CPU with integrated PROFIBUS DP interfaces. CPUs or communication modules with PROFIBUS DP interfaces enable distributed automation configuration with high speed and simple operation. Distributed I/O via PROFIBUS DP is treated from the user's perspective as centralized I/O (same configuration, addressing and programming).

Data transfer via Ethernet

The S7-1500 can be connected to an Industrial Ethernet bus system via an integrated PROFINET interface or a communication module.

Data transfer via PROFIBUS

SIMATIC S7-1500 (not S7-1500R/H) can be connected to a PROFIBUS bus system via a communication module or CPU with integrated PROFIBUS DP interfaces.

Data transfer via point-to-point communication modules

Efficient point-to-point connections can be realized using point-to-point communication modules.

Data transmission via IO-Link communication modules

Up to eight IO-Link devices can be connected via the CM 8xIO-Link communication module.

 

Find out more about our offer by visiting the tabs with Siemens-PLC and Schneider-PLC products. If the product you are looking for is not on our website or you have additional questions, please contact us at inquiry@plc-drives.com or directly at our representatives (addresses available in the "Contact" tab). We are able to supply you with all Siemens and Schneider PLC products, including those already withdrawn from production. Check our offer!